        進入中文版  繁體中文 前, 要設定延遲翻譯時間, 如100表示100ms,默認為0 var cookieDomain = "/"; //Cookie地址, 一定要設定, 通常為你的網址 var msgToTraditionalChinese = "繁體中文"; //默認切換為繁體時顯示的中文字符 var msgToSimplifiedChinese = "簡體中文"; //默認切換為簡體時顯示的中文字符 var translateButtonId = "translateLink"; //默認互換id translateInitilization(); 進入英文版  ENGLISH
        聯系我們

        電話: +86-550-7309278
        傳真: +86-550-7309288
        手機: +86-13905505237
        E-mail: 13905505237@163.com
        地址: 安徽省天長市經濟開發區天汊路128號
        QQ: 641289349
        QQ: 641289349

        產品展示 > 控制電纜 > > CONTROL CABLE FR-XLPE Insulated Conductors, CPE Jacket, 600V
        產品名稱 : CONTROL CABLE FR-XLPE Insulated Conductors, CPE Jacket, 600V
         放大產品                返回上一頁
        ←[上一個產品]              [下一個產品]→


        詳細說明:
        Applications
        As flame-retardant multi-conductor control, signal or power cables rated 600 volts, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial.

        Construction
        Stranded uncoated copper conductors, 30 mils FR-XLPE flame-retardant crosslinked polyethylene insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, cable tape, CPE jacket overall, surface printed.

        Standards
      1. Listed by UL as Type TC per Standard 1277 for Tray Cables.
      2. Cables UL listed for Direct Burial.
      3. Individual conductors pass UL VW-1 flame test.
      4. Individual conductors UL listed as Type XHHW-2.
      5. Overall jacket UL listed as Sunlight Resistant.
      6. Cables with grounding conductor UL listed for Open Wiring.
      7. Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hour test.
      8. Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
      9. Cables meet requirements of ICEA S-73-532, NEMA WC70 for Control Cables.

        Notes
         
      10. Cables may be supplied with an insulated ground and marked “Open Wiring.”
      11. Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request.
      12. Color Coding also available ICEA Method 1, Table E-1; power sizes, ICEA Method 4.

        Options
         
      13. Bare or Tinned Copper
      14. Flexible stranded conductors
      15. E1 or E2 color codes
      16. EPR Insulation
      17. PVC, CSPE, LSOH jackets
      18. Overall copper tape shield
      19. Overall copper braid shield
      20. Overall longitudinal corrugated copper shield
      21. Overall mylar tape shield with drain wire
      22. 1000 volt rated construction

        Consult us for a variety of alternate constructions for specific applications.


      23. 相關產品:
        CONTROL CABLE FR-XLPE Insulated Conductors, PVC Jacket, 600V
        CONTROL CABLE FR-XLPE Insulated Conductors, PVC Jacket, 600V
        CONTROL CABLE FR-XLPE Insulated Conductors, CU Shield, CPE Jacket, 600V
        CONTROL CABLE FR-XLPE Insulated Conductors, CU Shield, CPE Jacket, 600V
        聚氯乙烯絕緣及護套控制電纜
        聚氯乙烯絕緣及護套控制電纜
        Thermocouple Cable
        Thermocouple Cable